Documentation

From blank canvas to reviewed scenario.

A concise web guide to the core workflow. The application also includes complete context-sensitive documentation under Help → Documentation (F1).

01 · Install

Start with Python 3.10 or newer.

The current package is available from PyPI. Install it into an isolated Python environment, then launch the desktop application.

Terminal
pip install pyrateshield
pyrateshield

For the latest development version, clone the source repository from Codeberg and run pip install . inside it.

02 · First project

Establish scale before geometry.

  1. Load a floorplanOpen File → Floorplan & Scale, or work on a blank canvas.
  2. CalibrateDraw a ruler over a known length, enter that distance and apply calibration.
  3. Add source objectsPlace NM, CT or X-ray sources and enter workload, occupancy and source-specific inputs.
  4. Draw barriersCreate shielding presets, then assign them to the walls you draw over the plan.
  5. Place critical pointsMark occupied or otherwise important locations for exact evaluation.
03 · Calculate

Choose the model, then make the result readable.

Select Pre-computed (MCNP) or Point Kernel for the NM contribution and click Calculate. CT and X-ray contributions use the same source-specific scatter models with either choice.

Remember

The critical-point table does not update automatically after edits. Recalculate the scenario whenever an input, source, wall or setting changes.

Use display controls to tune dose range, colormap, opacity, logarithmic scaling and custom contour levels. These controls change presentation, not the underlying project geometry.

04 · Report

Preserve both the model and the evidence.

Save the PyrateShield project for future review. Export the canvas when a visual record is useful, and export the critical-point report to Excel for exact values and per-source breakdowns.

05 · Safety and limitations

Independent verification is mandatory.

PyrateShield is unverified decision-support software and is provided without warranty. Its outputs must not be the sole basis for shielding, construction, safety, clinical or financial decisions.

  • Confirm every geometry, workload, occupancy factor, material and unit.
  • Review model limitations, including scatter, mixed-material transmission and self-shielding assumptions.
  • Compare results with independent calculations, measurements or validated methods appropriate to your jurisdiction.
  • Have conclusions reviewed by appropriately qualified professionals.
06 · Further resources

Go deeper in the source documentation.